[Interface Signal]:Ethernet
[Serial Ports]:8
[Network Protocols]:IP, TCP/UDP, IPv4, APR, DHCP, DNS, HTTP, MQTT
[Operating Voltage]:DC 3.0-5.5V
[Size]:27*27*3mm
[Product weight]:32.3±1g
[Introduction]:The NS8-V2 Ethernet module is a surface-mount Ethernet serial server module that converts data from eight serial ports to Ethernet. Featuring multiple Modbus gateway modes and TCP/DUP/MQTT/HTTP IoT gateway modes, the Ethernet module can connect various serial devices and PLCs. The serial-to-Ethernet module utilizes an LCC package, making it easy to integrate onto PCBs.
| Serial number | Pins | Functional Description |
| 1 | GND | Common ground terminal, negative power input; |
| 2 | NC | The default setting is floating. |
| 3 | NC | The default setting is floating. |
| 4 | NC | The default setting is floating. |
| 5 | NC | The default setting is floating. |
| 6 | NC | The default setting is floating. |
| 7 | GND | Common ground terminal, negative power input; |
| 8 | GND | Common ground terminal, negative power input; |
| 9 | GND | Common ground terminal, negative power input; |
| 10 | GND | Common ground terminal, negative power input; |
| 11 | TXD6 | The serial port only supports 3.3V TTL data transmission. If it is connected to 5V, level conversion is required. |
| 12 | RXD6 | The serial port only supports 3.3V TTL data reception. If it is connected to 5V, level conversion is required. |
| 13 | TXD7 | The serial port only supports 3.3V TTL data transmission. If it is connected to 5V, level conversion is required. |
| 14 | RXD7 | The serial port only supports 3.3V TTL data reception. If it is connected to 5V, level conversion is required. |
| 15 | TXD2 | The serial port only supports 3.3V TTL data transmission. If it is connected to 5V, level conversion is required. |
| 16 | RXD2 | The serial port only supports 3.3V TTL data reception. If it is connected to 5V, level conversion is required. |
| 17 | TXD8 | The serial port only supports 3.3V TTL data transmission. If it is connected to 5V, level conversion is required. |
| 18 | RXD8 | The serial port only supports 3.3V TTL data reception. If it is connected to 5V, level conversion is required. |
| 19 | GND | Common ground terminal, negative power input; |
| 20 | GND | Common ground terminal, negative power input; |
| 21 | VCC | Power positive input, supports 3-5.5V input, can be used simultaneously with pin 22; |
| 22 | VCC | Power positive input, supports 3-5.5V input; can be used simultaneously with pin 21; |
| 23 | DATA8 | Serial port 8 data indicator pin, outputs 50ms square wave when there is data interaction; |
| 24 | LINK8 | Serial port 8 data link indicator, outputs low level when UDP mode is connected successfully; outputs low level when other modes are connected successfully, and outputs high level when no connection is made; |
| 25 | DATA7 | Serial port 7 data indicator pin, outputs 50ms square wave when there is data interaction; |
| 26 | LINK7 | Serial port 7 data link indicator, outputs low level when UDP mode is connected; outputs low level when other modes are connected successfully, and outputs high level when no connection is made; |
| 27 | DATA6 | Serial port 6 data indicator pin, outputs 50ms square wave when there is data interaction; |
| 28 | LINK6 | Serial port 6 data link indicator, outputs low level when UDP mode is connected; outputs low level when other modes are connected successfully, and outputs high level when no connection is made; |
| 29 | DATA5 | Serial port 5 data indicator pin, outputs 50ms square wave when there is data interaction; |
| 30 | LINK5 | Serial port 5 data link indicator, outputs low level when UDP mode is connected; outputs low level when other modes are connected successfully, and outputs high level when no connection is made; |
| 31 | TXD3 | The serial port only supports 3.3V TTL data transmission. If it is connected to 5V, level conversion is required. |
| 32 | RXD3 | The serial port only supports 3.3V TTL data reception. If it is connected to 5V, level conversion is required. |
| 33 | 485EN-2 | Serial port 2 RS485 enable pin, normally low, pulled high when sending data |
| 34 | 485EN-3 | Serial port 3 RS485 enable pin, normally low, pulled high when sending data |
| 35 | 485EN-4 | Serial port 4 RS485 enable pin, normally low, pulled high when sending data |
| 36 | 485EN-1 | Serial port 1 RS485 enable pin, normally low, pulled high when sending data |
| 37 | 485EN-8 | Serial port 8 RS485 enable pin, normally low, pulled high when sending data |
| 38 | 485EN-7 | Serial port 8 RS485 enable pin, normally low, pulled high when sending data |
| 39 | 485EN-6 | Serial port 6 RS485 enable pin, normally low, pulled high when sending data |
| 40 | 485EN-5 | Serial port 5 RS485 enable pin, normally low, pulled high when sending data |
| 41 | SPDLED | Network port data indicator |
| 42 | LINKLED | Network port connection indicator |
| 43 | RX+ | Ethernet receives RX+ signal; |
| 44 | RX- | Ethernet receives RX-signal; |
| 45 | TX+ | Ethernet sends TX+ signal; |
| 46 | TX- | Ethernet sends TX-signal; |
| 47 | RESTORE | Reset pin, pull low for more than 5 seconds to take effect |
| 48 | TXD1 | The serial port only supports 3.3V TTL data transmission. If it is connected to 5V, level conversion is required. |
| 49 | RXD1 | The serial port only supports 3.3V TTL data reception. If it is connected to 5V, level conversion is required. |
| 50 | NC | The default setting is floating. |
| 51 | NC | The default setting is floating. |
| 52 | NC | The default setting is floating. |
| 53 | 3.3V | Output voltage 3.3V; |
| 54 | GND | Common ground terminal, negative power input; |
| 55 | NC | The default setting is floating. |
| 56 | NC | The default setting is floating. |
| 57 | NC | The default setting is floating. |
| 58 | NC | The default setting is floating. |
| 59 | NRST | Module reset, pull down for more than 1ms to take effect |
| 60 | NET | Network cable connection indicator, detect the network cable is inserted, the output is low, the network cable is not detected, the output is high |
| 61 | TXD4 | The serial port only supports 3.3V TTL data transmission. If it is connected to 5V, level conversion is required. |
| 62 | RXD4 | The serial port only supports 3.3V TTL data reception. If it is connected to 5V, level conversion is required. |
| 63 | TXD5 | The serial port only supports 3.3V TTL data transmission. If it is connected to 5V, level conversion is required. |
| 64 | RXD5 | The serial port only supports 3.3V TTL data reception. If it is connected to 5V, level conversion is required. |
| 65 | LINK1 | Serial port 1 data link indicator, outputs low level when UDP mode is connected; outputs low level when other modes are connected successfully, and outputs high level when no connection is made; |
| 66 | DATA1 | Serial port 1 data indicator pin, outputs 50ms square wave when there is data interaction; |
| 67 | LINK2 | Serial port 2 data link indicator, outputs low level when UDP mode is connected; outputs low level when other modes are connected successfully, and outputs high level when no connection is made; |
| 68 | DATA2 | Serial port 2 data indicator pin, outputs 50ms square wave when there is data interaction; |
| 69 | LINK3 | Serial port 3 data link indicator, outputs low level when UDP mode is connected; outputs low level when other modes are connected successfully, and outputs high level when no connection is made; |
| 70 | DATE3 | Serial port 3 data indicator pin, outputs 50ms square wave when there is data interaction; |
| 71 | LINK4 | Serial port 4 data link indicator, UDP mode outputs low level; other modes output low level when the connection is successful, and output high level when there is no connection; |
| 72 | DATA4 | Serial port 4 data indicator pin, outputs 50ms square wave when there is data interaction; |