[Interface]:UART(RS485、RS422、RS232)、ethernet(RJ45)
[Size]:82*84*25mm
[Weigtht]:126g ± 5g
[Introduction]:NB114 is a serial server that realizes serial data ⇌ Ethernet data conversion.The product comes with RJ45 interface and guide rail installation.With multiple Modbus gateway modes, it can meet the networking functions of various serial devices/PLCs.
No. | Name | Function | Description |
1 | RS232 | RS232 interface | Standard DB9-RS-232 female line sequence; |
2 | 485-A(T+) | RS485/RS422 interface | A of RS-485 interface, T+ sent by RS-422; |
3 | 485-B(T-) | RS485/RS422 interface | B of RS-485 interface, T- sent by RS-422; |
4 | (R+) | RS422 interface (R+) | R+ received by RS-422; |
5 | (R-) | RS422 interface (R-) | R- received by RS-422; |
6 | PWR | Power Indicator | Power on: red light on; |
Power off: light off; | |||
7 | DATA | Data sending and receiving indicator | 3 seconds before power on: fast flashing; |
Waiting for network cable: always on; | |||
Data sent and received: blue light and green light flashing; | |||
No data sent and received: light off; | |||
8 | LINK | Link connection light | Connection successful: green light on; |
No connection: light off; | |||
UDP mode always on; | |||
9 | DC-IN | DC female power input | DC 8~28V input, do not input with Phoenix terminal at the same time; |
10 | VCC | DC power input | 3.81mm Phoenix terminal, DC 8~28V positive pole, do not input with DC head at the same time; |
11 | GND | DC power output | 3.81mm Phoenix terminal, DC 8~28V negative pole, do not input with DC head at the same time; |
12 | Reload | Factory reset button | Press and hold for 5 seconds The device can be restored to factory default in seconds; |
13 | Ethernet | Network interface | Standard RJ45 interface; |