[Communication Interface]:RS485
[Communication distance]: 5km
[Operating Voltage]:DC 8-28V
[Installation Method]:DIN-Rail Mounting
[Size]:113*72*65mm
[Product weight]:150 ± 5g
[Introduction]:The wireless intercommunication switch is a terminal device that uses LoRa modulation technology to achieve wireless remote transmission of switching values. It supports four digital inputs (DIs) for data acquisition and four relay outputs (DOs) for control. Operating in the 850.125-930.125 MHz frequency band, its core function is to enable remote synchronous control. It requires no wiring and is highly user-friendly, allowing users to quickly integrate it into their own systems. It accepts a DC input voltage of 8-28 V. It is coated with a conformal coating that is resistant to mildew, moisture, and salt spray.
| Modem | Distancekm | Antenna | Operating VoltageV | Communication Interface | Product weightg | Installation method | Features | Manual | Sample |
|---|---|---|---|---|---|---|---|---|---|
| E860-DTU(8080-400SL30)-V2 | 10 | SMA antenna mount (external screw, internal hole) | DC 8-28 | RS485 | 192±5 | DIN-rail mounting | LoRa remote synchronous transmission switch | ||
| E860-DTU(4040-400SL30)-V2 | 10 | SMA antenna mount (male thread, female hole) | DC 8-28 | RS485 | 150±5 | DIN-rail mounting | LoRa remote simultaneous transmission switch with 4 DI and 4 DO channels | ||
| E860-DTU(2020-400SL30)-V2 | 10 | SMA antenna mount (external screw, internal hole) | DC 8-28 | RS485 | 110±5 | DIN-rail mounting | LoRa remote synchronous transmission switch | ||
| E860-DTU(8080-400SL22)-V2 | 5 | SMA antenna mount (male thread, female hole) | DC 8-28 | RS485 | 189±5g | DIN-rail mounting | 8-channel DI + 8-channel DO LoRa remote simultaneous transmission switch | ||
| E860-DTU(4040-400SL22)-V2 | 5 | SMA antenna mount (male thread, female hole) | DC 8-28 | RS485 | 150±5 | DIN-rail mounting | LoRa remote synchronous transmission switch with 4 DI and 4 DO | ||
| E860-DTU(2020-400SL22)-V2 | 5 | SMA antenna mount (external screw, internal hole) | DC 8-28 | RS485 | 110±5 | DIN-rail mounting | LoRa remote synchronous transmission switch | ||
| E860-DTU(1010-400SL22)-V2 | 5 | SMA antenna mount (male thread, female hole) | DC 8-28 | RS485 | 77±5 | DIN-rail mounting | LoRa remote synchronous transmission switch | ||
| E860-DTU(8080-900SL30)-V2 | 10 | SMA Antenna Mount (External Thread, Internal Hole) | DC 8-28 | RS485 | 192±5 | DIN-Rail Mount | 900 Band LoRa Remote Synchronous Transmission Switch | ||
| E860-DTU(4040-900SL30)-V2 | 10 | SMA Antenna Mount (External Thread, Internal Hole) | DC 8-28 | RS485 | 150±5 | DIN-Rail Mount | 900 Band LoRa Remote Synchronous Transmission Switch | ||
| E860-DTU(2020-900SL30)-V2 | 10 | SMA Antenna Mount (External Thread, Internal Hole) | DC 8-28 | RS485 | 110±5 | DIN-Rail Mount | 900 Band LoRa Remote Synchronous Transmission Switch | ||
| E860-DTU(8080-900SL22)-V2 | 5 | SMA Antenna Mount (External Thread, Internal Hole) | DC 8-28 | RS485 | 192±5 | DIN-Rail Mount | 900 Band LoRa Remote Synchronous Transmission Switch | ||
| E860-DTU(4040-900SL22)-V2 | 5 | SMA Antenna Mount (External Thread, Internal Hole) | DC 8-28 | RS485 | 150±5 | DIN-Rail Mount | 900 Band LoRa Remote Synchronous Transmission Switch | ||
| E860-DTU(2020-900SL22)-V2 | 5 | SMA antenna mount (external screw, internal hole) | DC 8-28 | RS485 | 110±5 | DIN-rail mounting | 900 band LoRa remote synchronous transmission switch | ||
| E860-DTU(1010-900SL22)-V2 | 5 | SMA Antenna Mount (External Thread, Internal Hole) | DC 8-28 | RS485 | 77±5 | DIN-Rail Mount | 900Mhz LoRa Remote Synchronous Intercommunication Switch | ||
| E860-DTU(8080-400SL) | 10 | SMA antenna base (external screw and internal hole) | DC 8~28 | RS485 | 226±5 | Guide rail installation | Realize remote synchronous control | ||
| E860-DTU(2020-400SL)A | 10 | SMA antenna base (external screw inner hole) | AC 85~265 | RS485 | 194±5 | Rail installation | LoRa remote synchronization control remote control switch | ||
| E860-DTU(4040-400SL)A | 10 | SMA antenna base (external screw inner hole) | AC 85~265 | RS485 | 206±5 | Rail installation | LoRa remote synchronization switch control | ||
| E860-DTU(8080-400SL)A | 10 | SMA antenna base (external screw inner hole) | AC 85~265 | RS485 | 236±5 | Rail installation | LORA remote synchronized switch control | ||
| E860-DTU(2020-400SL) | 10 | SMA antenna base (external screw inner hole) | DC 8~28 | RS485 | 184±5 | Rail installation | LoRa remote synchronization control remote control switch | ||
| E860-DTU(4040-400SL) | 10 | SMA antenna base (external screw inner hole) | DC 8~28 | RS485 | 196±5 | Rail installation | LoRa remote synchronization control remote control switch | ||
| E831-RTU(8080T-485) | - | - | DC 8-28 | RS485 | 256±5 | Crimping method | 16-channel network IO controller | ||
| K61-DL20 | 4 | - | DC 8-28 | RS485 | 164±5 | - | Switching quantity synchronous remote transmission | ||
| E830-DTU(2R2-433L)-V8 | 8 | - | DC 8-28 | RS485 | 130±5 | Crimping method | 2 channels, support Modbus RTU |