[Communication Interface]:RS485
[Communication distance]:5km
[Operating Voltage]: DC 8-28V
[Installation method]: DIN-Rail Mounting
[Size]:113*37*65mm
[Product weight]: 77 ± 5g
[Introduction]:The wireless intercommunication switch is a terminal device that uses LoRa modulation technology to achieve wireless remote transmission of switching values. It supports collecting switching inputs (DI) and controlling relay outputs (DO). Operating in the 850.125-930.125 MHz frequency band, its core function is to achieve remote synchronous control. It requires no wiring and is highly user-friendly, allowing users to quickly integrate it into their own systems. It has a DC input voltage of 8-28 V and is coated with a conformal coating that is resistant to mold, moisture, and salt spray.
| Modem | Distancekm | Antenna | Operating VoltageV | Communication Interface | Product weightg | Installation method | Features | Manual | Sample |
|---|---|---|---|---|---|---|---|---|---|
| E860-DTU(8080-400SL30)-V2 | 10 | SMA antenna mount (external screw, internal hole) | DC 8-28 | RS485 | 192±5 | DIN-rail mounting | LoRa remote synchronous transmission switch | ||
| E860-DTU(4040-400SL30)-V2 | 10 | SMA antenna mount (male thread, female hole) | DC 8-28 | RS485 | 150±5 | DIN-rail mounting | LoRa remote simultaneous transmission switch with 4 DI and 4 DO channels | ||
| E860-DTU(2020-400SL30)-V2 | 10 | SMA antenna mount (external screw, internal hole) | DC 8-28 | RS485 | 110±5 | DIN-rail mounting | LoRa remote synchronous transmission switch | ||
| E860-DTU(8080-400SL22)-V2 | 5 | SMA antenna mount (male thread, female hole) | DC 8-28 | RS485 | 189±5g | DIN-rail mounting | 8-channel DI + 8-channel DO LoRa remote simultaneous transmission switch | ||
| E860-DTU(4040-400SL22)-V2 | 5 | SMA antenna mount (male thread, female hole) | DC 8-28 | RS485 | 150±5 | DIN-rail mounting | LoRa remote synchronous transmission switch with 4 DI and 4 DO | ||
| E860-DTU(2020-400SL22)-V2 | 5 | SMA antenna mount (external screw, internal hole) | DC 8-28 | RS485 | 110±5 | DIN-rail mounting | LoRa remote synchronous transmission switch | ||
| E860-DTU(1010-400SL22)-V2 | 5 | SMA antenna mount (male thread, female hole) | DC 8-28 | RS485 | 77±5 | DIN-rail mounting | LoRa remote synchronous transmission switch | ||
| E860-DTU(8080-900SL30)-V2 | 10 | SMA Antenna Mount (External Thread, Internal Hole) | DC 8-28 | RS485 | 192±5 | DIN-Rail Mount | 900 Band LoRa Remote Synchronous Transmission Switch | ||
| E860-DTU(4040-900SL30)-V2 | 10 | SMA Antenna Mount (External Thread, Internal Hole) | DC 8-28 | RS485 | 150±5 | DIN-Rail Mount | 900 Band LoRa Remote Synchronous Transmission Switch | ||
| E860-DTU(2020-900SL30)-V2 | 10 | SMA Antenna Mount (External Thread, Internal Hole) | DC 8-28 | RS485 | 110±5 | DIN-Rail Mount | 900 Band LoRa Remote Synchronous Transmission Switch | ||
| E860-DTU(8080-900SL22)-V2 | 5 | SMA Antenna Mount (External Thread, Internal Hole) | DC 8-28 | RS485 | 192±5 | DIN-Rail Mount | 900 Band LoRa Remote Synchronous Transmission Switch | ||
| E860-DTU(4040-900SL22)-V2 | 5 | SMA Antenna Mount (External Thread, Internal Hole) | DC 8-28 | RS485 | 150±5 | DIN-Rail Mount | 900 Band LoRa Remote Synchronous Transmission Switch | ||
| E860-DTU(2020-900SL22)-V2 | 5 | SMA antenna mount (external screw, internal hole) | DC 8-28 | RS485 | 110±5 | DIN-rail mounting | 900 band LoRa remote synchronous transmission switch | ||
| E860-DTU(1010-900SL22)-V2 | 5 | SMA Antenna Mount (External Thread, Internal Hole) | DC 8-28 | RS485 | 77±5 | DIN-Rail Mount | 900Mhz LoRa Remote Synchronous Intercommunication Switch | ||
| E860-DTU(8080-400SL) | 10 | SMA antenna base (external screw and internal hole) | DC 8~28 | RS485 | 226±5 | Guide rail installation | Realize remote synchronous control | ||
| E860-DTU(2020-400SL)A | 10 | SMA antenna base (external screw inner hole) | AC 85~265 | RS485 | 194±5 | Rail installation | LoRa remote synchronization control remote control switch | ||
| E860-DTU(4040-400SL)A | 10 | SMA antenna base (external screw inner hole) | AC 85~265 | RS485 | 206±5 | Rail installation | LoRa remote synchronization switch control | ||
| E860-DTU(8080-400SL)A | 10 | SMA antenna base (external screw inner hole) | AC 85~265 | RS485 | 236±5 | Rail installation | LORA remote synchronized switch control | ||
| E860-DTU(2020-400SL) | 10 | SMA antenna base (external screw inner hole) | DC 8~28 | RS485 | 184±5 | Rail installation | LoRa remote synchronization control remote control switch | ||
| E860-DTU(4040-400SL) | 10 | SMA antenna base (external screw inner hole) | DC 8~28 | RS485 | 196±5 | Rail installation | LoRa remote synchronization control remote control switch | ||
| E831-RTU(8080T-485) | - | - | DC 8-28 | RS485 | 256±5 | Crimping method | 16-channel network IO controller | ||
| K61-DL20 | 4 | - | DC 8-28 | RS485 | 164±5 | - | Switching quantity synchronous remote transmission | ||
| E830-DTU(2R2-433L)-V8 | 8 | - | DC 8-28 | RS485 | 130±5 | Crimping method | 2 channels, support Modbus RTU |