E810-R41 Industrial grade isolated RS485 hub photoelectric isolation, 4-way to 1-way RS-485

[Data interface]:RS485

[Working voltage]: DC 9~40V

[Protection level]:Industrial EMC level 3

[Product size]:120*72*34mm

[Introduction]:E810-R41 is a 4-channel RS-485 to 1-channel RS-485 buffered isolation repeater launched by Ebyte. It uses photoelectric isolation technology to protect the master and slave stack devices from interference. The circuit is designed using EMC level 3 standards, which can effectively isolate the damage caused by lightning strikes and static electricity to the equipment. No configuration is required, and transparent data transmission between the master and slave interfaces.

PIN
Serial NumberNameillustrate
1MA1-485A5.08mm terminal block, MA1-485-A interface
2MA1-485B5.08mm terminal block, MA1-485-B interface
3GND5.08mm terminal block, output digital signal ground
4MA2-485A5.08mm terminal block, MA1-485-A interface
5MA2-485B5.08mm terminal block, MA1-485-B interface
6MA3-485A5.08mm terminal block, MA1-485-A interface
7MA3-485B5.08mm terminal block, MA1-485-B interface
8GND5.08mm terminal block, output digital signal ground
9MA4-485A5.08mm terminal block, MA1-485-A interface
10MA4-485B5.08mm terminal block, MA1-485-B interface
11SL-GND5.08mm terminal block, output digital signal ground
12SL-485A5.08mm terminal block, SL-485-A interface
13SL-485B5.08mm terminal block, SL-485-B interface
14NCNot open yet
15GND5.08mm terminal block, digital signal ground
16RELOAD5.08mm terminal block, restore factory settings, pull down for 5-10 seconds to take effect
17NCNot open yet
18DC 9~40V-VCC5.08mm terminal block, positive power input
19DC 9~40V-GND5.08mm terminal block, power ground, and digital signal ground are not interoperable
20ON5.08mm terminal block, connected to earth terminal
21LED-PWRPower indicator light
22LED-RUNThe running indicator light flashes during normal operation and stays on after entering the configuration.
23LED-SLThe slave interface data sending and receiving indicator light flashes when there is data interaction.
24LED-MA1Main interface 1 data sending and receiving indicator light, flashes when there is data interaction
25LED-MA2Main interface 2 data sending and receiving indicator light, flashes when there is data interaction
26LED-MA3Main interface 3 data sending and receiving indicator light, flashes when there is data interaction
27LED-MA4Main interface 4 data sending and receiving indicator light, flashes when there is data interaction