[Data interface]:RS485
[Working voltage]:DC 8~28V
[Protection level]:Industrial EMC level 3
[Product size]:120*72*34mm
[Introduction]:E810-R41 is a 4-channel RS-485 to 1-channel RS-485 buffered isolation repeater launched by Ebyte.The shell adopts three-proof coating, which is Anti-Fungal, Anti-Humidity, and Anti-Salt Spray.It uses photoelectric isolation technology to protect the master and slave stack devices from interference. The circuit is designed using EMC level 3 standards, which can effectively isolate the damage caused by lightning strikes and static electricity to the equipment. No configuration is required, and transparent data transmission between the master and slave interfaces.
| Serial Number | Name | illustrate |
| 1 | MA1-485A | 5.08mm terminal block, MA1-485-A interface |
| 2 | MA1-485B | 5.08mm terminal block, MA1-485-B interface |
| 3 | GND | 5.08mm terminal block, output digital signal ground |
| 4 | MA2-485A | 5.08mm terminal block, MA1-485-A interface |
| 5 | MA2-485B | 5.08mm terminal block, MA1-485-B interface |
| 6 | MA3-485A | 5.08mm terminal block, MA1-485-A interface |
| 7 | MA3-485B | 5.08mm terminal block, MA1-485-B interface |
| 8 | GND | 5.08mm terminal block, output digital signal ground |
| 9 | MA4-485A | 5.08mm terminal block, MA1-485-A interface |
| 10 | MA4-485B | 5.08mm terminal block, MA1-485-B interface |
| 11 | SL-GND | 5.08mm terminal block, output digital signal ground |
| 12 | SL-485A | 5.08mm terminal block, SL-485-A interface |
| 13 | SL-485B | 5.08mm terminal block, SL-485-B interface |
| 14 | NC | Not open yet |
| 15 | GND | 5.08mm terminal block, digital signal ground |
| 16 | RELOAD | 5.08mm terminal block, restore factory settings, pull down for 5-10 seconds to take effect |
| 17 | NC | Not open yet |
| 18 | DC 9~40V-VCC | 5.08mm terminal block, positive power input |
| 19 | DC 9~40V-GND | 5.08mm terminal block, power ground, and digital signal ground are not interoperable |
| 20 | ON | 5.08mm terminal block, connected to earth terminal |
| 21 | LED-PWR | Power indicator light |
| 22 | LED-RUN | The running indicator light flashes during normal operation and stays on after entering the configuration. |
| 23 | LED-SL | The slave interface data sending and receiving indicator light flashes when there is data interaction. |
| 24 | LED-MA1 | Main interface 1 data sending and receiving indicator light, flashes when there is data interaction |
| 25 | LED-MA2 | Main interface 2 data sending and receiving indicator light, flashes when there is data interaction |
| 26 | LED-MA3 | Main interface 3 data sending and receiving indicator light, flashes when there is data interaction |
| 27 | LED-MA4 | Main interface 4 data sending and receiving indicator light, flashes when there is data interaction |